    ÎÒ¿çÈë´æ´¢ÐÐÒµµÄÃż÷ʱ¼ä²»³¤£¬µ«ÊÇÔÚÕâ¶Î¶Ì¶ÌµÄʱ¼äÀ¾­ÀúÁËÎÞÊýµÄµÚÒ»´Î¡£×îÈÃÎÒÄÑÍüµÄʵʩ¾­ÑéÊÇÈëÐкóµÚÒ»´ÎΪ¿Í»§ÉÏÃÅʵʩ¡£ÄÇÌìBossͻȻ¸æËßÎÒҪȥɽ¶«³ö²î¸øÓû§½â¾öÎÊÌ⣬Ҫ֪µÀÔÚÄÇÒÔǰ£¬ÎÒ»¹´ÓÀ´Ã»¶ÀÁ¢ÉÏßøÓû§·þÎñ¹ý£¬Òò´Ëһ·ÉÏÐÄÀﲻͣµÄ´ò×ÅС¹Ä£¬¾Íµ£ÐÄ×Ô¼ºÂ¶ÇÓ¡£

Óû§±¨ÐÞ£¬³¬ÊÐÒµÎñ´óÊÜÓ°Ïì

    ¸Õµ½¿Í»§ÄÇÀ¾Í±»¿Í»§µÄÍø¹ÜԱСÁõÒ»°Ñ×§½øÁË»ú·¿¡£Ô­À´£¬¿Í»§Êǵ±µØÒ»¼Ò½ÏÓйæÄ£µÄÍâ×ÊÁ¬Ëø³¬ÊУ¬Ò»Ö±ÒÀÀµÕâÌ׺ǫ́ϵͳ½øÐÐÂòÂô¼ÇÕ˺ͽáË㡣ijÌìÔçÉÏ£¬ÒµÎñÈËԱͻȻ˵Öն˽áÕËϵͳÎÞ·¨Ê¹Óã¬Ð¡Áõ·¢ÏÖÊÇ·þÎñÆ÷¶ËÊý¾Ý¿âÎÞ·¨·ÃÎÊ£¬ÓÚÊDZ»ÆÈÆôÓÃÒ»Ì×±¸Ó÷þÎñÆ÷Ö§³ÅÒµÎñ¡£

    µ«ÊDZ¸Ó÷þÎñÆ÷ÐÔÄÜÔ¶Ô¶²»ÄÜÂú×ãÊý¾ÝƵ·±¶ÁÈ¡µÄ¸ººÉÐèÇó£¬ÔÚ³¬ÊÐÒµÎñ×æµÄʱºò£¬Ò²ÊÇ·þÎñÆ÷µ±»úÖØÆð×îÆµ·±µÄʱºò£¬¶øÇÒвúÉúµÄÊý¾Ý¶¼ÐèÒª²ÆÎñ¼Ó°à£¬ÊÖ¹¤ÊäÈëµ½Ô­ÓеÄϵͳÖвÅÄÜÍê³Éµ±Èպ͵±ÔµĽáËã¡£ËùÓеÄÒµÎñÈËÔ±¶¼¶ÔСÁõÔ¹ÉùÔØµÀ£¬Á¬Ò»ÏòºÍ°ª¿ÉÇ׵ľ­ÀíÕâÁ½ÌìÒ»¼ûµ½Ð¡ÁõÁ³É«¾ÍÒõ³ÁÏÂÀ´¡£

    Ìý¹ýÁËСÁõµÄË߿࣬ÎÒÏêϸ²ì¿´ÁËÓû§µÄ»·¾³¡£³¬ÊÐʹÓÃÁË2̨IA¼Ü¹¹µÄ·þÎñÆ÷¹Ò½Óһ̨SCSIµÄ´ÅÅÌÕóÁÐ×öË«»úϵͳ¡£Ö÷»ú²ÉÓÃWindows2000 advanced server²Ù×÷ϵͳ£¬Ê¹ÓÃÒ»Ì׳¬ÊÐרÓõÄÕÊÎñϵͳ£¬ºǫ́ÊÇSQLServer2000¡£

    Á½Ì¨·þÎñÆ÷²ÉÓÃÁËWindowsϵͳ×Ô´øµÄMSCS¹¤×÷ÔÚActive£­PassiveµÄÖ÷´ÓģʽϹ¤×÷£¬MSCS¼ì²â¡¢¹ÜÀí¡¢Çл»Ë«»úµÄ×ÊÔ´×飬ÒÔ±£Ö¤SQL·þÎñÒ»Ö±ÄÜÕý³£ÔËÐС£ÓÉÓÚ³¬ÊÐӪҵʱ¼ä½Ï³¤£¬·þÎñÆ÷°×Ìì´Ó8:30¿ªÒµºóÒ»Ö±´¦ÓÚÔËÐÐ״̬£¬ÌṩËùÓÐÊý¾Ý¿âµÈÈí¼þ·þÎñ£¬¶ÔÊý¾Ý½øÐдæÈ¡£»ÍíÉÏ20:00¿Í»§¶Ë¹Ø±Õ£¬Í£Ö¹·þÎñÇëÇó£»22:00ÀûÓÃSQLÄÚÖõĹÜÀí¹¤¾ß¶ÔÖ÷»úÊý¾Ý½øÐб¸·Ý£¬°Ñ·þÎñÆ÷ÉϵÄÊý¾Ý±¸·Ýµ½´ÅÅÌÉÏ¡£

    µ±Êý¾Ý¿â²»¿É·ÃÎʵĹÊÕÏ·¢Éúºó£¬Ð¡ÁõÏÈÆô¶¯ÁËÒ»Ì×±¸ÓõķþÎñÆ÷×÷ΪÕÊÎñϵͳ£¬È»ºó²é¿´Ö÷»úµÄʼþ²é¿´Æ÷£¬·¢ÏÖÖ÷»úºÍ±¸»ú¶¼ÓÐID2¡¢5¡¢14µÄ±¨´í£¬Ê±¼äΪǰһÌìÍíÉÏ22:01£¨¿ªÊ¼±¸·ÝµÄʱ¼ä£©¡£Íø¹ÜÔ±ÖØÐÂÆô¶¯´ÅÅÌÕóÁУ¬Êý¾Ý¿âÓֿɱ»ÖØÐ·ÃÎÊÁË¡£±¾À´Ð¡Áõ°ÑÒµÎñϵͳÇл»»ØÀ´ÒÔΪûÊÂÁË£¬µ«ÊǵڶþÌì·¢ÉúͬÑùµÄ¹ÊÕÏ£¬ÖØÆô´ÅÅÌÕóÁкó£¬Êý¾Ý¿âÓÖ¿ÉÖØÐ±»·ÃÎÊ¡£ËæºóÁ¬ÐøµÄ¼¸ÌìÄÚ¶¼·¢ÉúͬÑùµÄ¹ÊÕÏ¡£

    ¾­¹ý³õ²½Åжϣ¬ÎÒÈÏΪÎÊÌâÓ¦¸Ã³öÔÚÊý¾ÝÁ¬½ÓÉÏ£¬ÓÚÊDzÉÓÃÅųý·¨£¬ÏȺó¸ü»»·þÎñÆ÷µ½ÕóÁеÄÄÚÍⲿÏßÀ¡¢SCSIÖÕ½áÆ÷¡¢´ÅÅÌÕóÁпØÖÆÆ÷ÒÔ¼°ÕûÌ×´ÅÅÌÕóÁУ¬µ«ÊÇÎÊÌâÈÔÈ»´æÔÚ£¬×îºó¸ÄÓÃÁËÍâ²åSCSI¿¨£¬×´¿öÁ¼ºÃ¡£ÎÒ×ÜËã¿ÉÒԻر±¾©¸úBoss½»²îÁË¡£

»Ø¾©²âÊÔ£¬ÎÊÌâµÄ¸ùÔ´ÔÚÄÄÀ
    ÎÊÌâÓ¦¸ÃÊǸæÒ»¸ö¶ÎÂäÁË£¬µ«Êǻر±¾©µÄ·;ÉÏÎÒȴʼÖÕûÏëÃ÷°×£¬ÎªÊ²Ã´°ÑÄÚÖÃSCSI»»³ÉÍâÖÃSCSI¾Í½â¾öÁËÎÊÌâÄØ£¿ÏÖÔÚ¿´À´£¬µ±Ê±µÄÅжϸüÏñÊÇÆ¾×ÅÖ±¾õ×ö³öÀ´µÄ¡£

    »Øµ½±±¾©ºó£¬ÎÒÔÚʵÑéÊÒÖÐÄ£ÄâÓû§ÁËÕæÊµ»·¾³£¬ÔÚDisk ArrayÉÏ»®·ÖÁË4¸öSlice·Ö±ðÓ³Éäµ½ÁËLUN1¡¢LUN2¡¢LUN3¡¢LUN4£¬²¢ÅäÖúÃSQL SERVER2000¡£
    1¡¢ ·þÎñÇл»£¬´óÊý¾Ý£¨Ô¼2GB£©ÔÚ²»Í¬µÄ·ÖÇøÖ®¼ä¡¢Í¨¹ýÍøÉÏÁÚ¾Ó¹²ÏíÎļþ¼ÐÖп½±´¡£
    2¡¢ Í¨¹ý¶Ô¸÷·ÖÇøÔËÐÐIOmeter 24Сʱ¡£
    3¡¢ ²ÉÓÃÇ¿ÖÆÊֶνûÓÃPrivate net£¬Public netʹÓõÄÊÇ»ìºÏͨѶ£¬ÔÚ¶ÔÍâ·þÎñµÄͬʱҲ·¢ËÍÐÄÌøÐźš£
    4¡¢ Èç¹ûÇ¿ÖÆ½«Server1µÄSCSIÏßÀ°γö£¬ÏàÁ¬·þÎñÆ÷»ù±¾Ì±»¾£¬¼¯ÈºÇл»·þÎñÕý³£¡£

---------------------------------------------------------------------------------------------------------
Çý¶¯³ÌÐòÔÚ \Device\Scsi\adpu160m2 Éϼì²âµ½¿ØÖÆÆ÷´íÎó¡£
Êý¾Ý:
0000: 0f 00 10 00 01 00 6a 00   ......j.
0008: 00 00 00 00 0b 00 04 c0   .......À
0010: 50 50 00 c1 00 00 00 00   PP.Á....
0018: 49 00 00 00 00 00 00 00   I.......
0020: 00 00 00 00 00 00 00 00   ........
0028: 00 00 00 00 00 00 00 00   ........
0030: 02 00 00 00 06 00 00 00   ........
ʼþÀàÐÍ: ¾¯¸æ
ʼþÀ´Ô´: Disk
ʼþÖÖÀà: ÎÞ
ʼþ ID: 51
ÈÕÆÚ:  ¡Á¡Á¡Á¡Á-¡Á¡Á-¡Á¡Á
ʱ¼ä:  ¡Á¡Á:¡Á¡Á:¡Á¡Á
Óû§:  N/A
¼ÆËã»ú: NT2
ÃèÊö:
´«ºôÆÚ¼äÔÚÉ豸 \Device\Harddisk3\DR3 Éϼì²âµ½Ò»¸ö´íÎó¡£
Êý¾Ý:
0000: 04 00 22 00 01 00 72 00   .."...r.
0008: 00 00 00 00 33 00 04 80   ....3..€
0010: 2d 01 00 00 00 00 00 00   -.......
0018: 00 00 00 00 00 00 00 00   ........        
---------------------------------------------------------------------------------------------------------

    É豸 \Device\Scsi\adpu160m2 ûÓÐÔÚ´«ÊäµÈ´ýʱ¼äÄÚÏìÓ¦¡£Çý¶¯³ÌÐòÔÚ \Device\Scsi\adpu160m2 Éϼì²âµ½¿ØÖÆÆ÷´íÎó¡£ÕâÁ½¸öÐÅÏ¢±íʾ´ÓwindowsÖз¢³öµÄÇëÇóÃüÁîûÓе½´ïÖ¸¶¨µÄÍâ½Ó´ÅÅÌÖУ¬Í¬Ê±ÓÉÓÚÁ¬½ÓÖжϣ¬windowsϵͳ¿ªÊ¼³öÏÖûÓÐÏìÓ¦¡£

[1] [2] ÏÂÒ»Ò³

¡¾Ôð±à:huangchunmei¡¿
Ïà¹ØÎÄÕÂ
SCSIºÍSATAµÄÆÀ±ÈÓëÑ¡Ôñ
ÎÒ¹úÊ×´ÎÍÆ³ö¾ßÓÐ×ÔÖ÷֪ʶ²úȨµÄÍøÂç´æ´¢Éè
HPÍÆ³öÁ½¿îD2DÉ豸 Ö÷¹¥SMB±¸·Ý
NetgearÉý¼¶µÍ¶ËNASÉ豸 ÌáËÙÖÁǧÕ×
½Ò¿ªSATAºÍSCSIÖ®¼äµÄ¶÷Ô¹Çé³ð
¸ß¶ËÍøÂç´æ´¢É豸µÄ²É¹ºÎóÇøÓë×¢ÒâÊÂÏî
SAS£ºÔÝʱÓëSCSI²¢´æ È¡´úSCSIÖ¸ÈÕ¿É´ý
×îÐÂÎÄÕÂ
¡¤Å̵ãÓ²ÅÌÁìÓòµÄ¾Å´ó»ù´¡¼¼Êõ
¡¤´æ´¢½²ÌãºÏê½âËÄ´óRAID´æ´¢
¡¤ÆÊÎöÎļþÐéÄ⻯ÒÔ¼°ËÄÖÖSANÐéÄâ¼Ü¹¹
¡¤Éî¶È½âÎöRAIDÀàÐÍ È«ÃæÍ¸ÊÓRAID 10ÓÅ
¡¤´ÅÅÌÕóÁÐÈý´ó¹Ø¼ü²¿¼þ
¡¤È«·½Î»½âÎöÐéÄâ´ø¿âÓÅÊÆÌØµã
¡¤ÔÆ´æ´¢Ó¦¸ÃÓÃÔÚʲôÑùµÄÒµÎñϵͳÖÐ
¡¡ÎÄÕÂÆÀÂÛ
¡¡¾«²ÊÓÑÇéÍÆ¼ö
¡¤AspÔ´Âë PHPÔ´Âë
¡¤CGIÔ´Âë JSPÔ´Âë
¡¤½¨Õ¾Êé¼®½Ì³Ì
¡¤·þÎñÆ÷Èí¼þ .netÔ´Âë
¡¤½¨Õ¾¹¤¾ßÈí¼þ
¡¤IDC×ÊѶ´óÈ«
¡¤»ú·¿Æ·ÖÊÍòÀïÐÐ
¡¤IDCÍйܱر¸ÖªÊ¶
¡¤È«¹úIDC±¨¼Û
¡¤ÍøÕ¾ÍƹãÓÅ»¯
ÐÐÒµÐÅÏ¢¹Ø×¢  

HDS´æ´¢Ñз¢ÌåϵÓë

2008µçÄÔÕ¹Å̵㣺
¡¤ÈüÃÅÌú¿Ë·¢²¼FileStoreÔÆ´æ´¢Æ½Ì¨
¡¤HDS·¢²¼Content Platform Ãé×¼ÔÆ
¡¤ÆóÒµ¿¼ÂÇ»ùÓÚÔÆµÄµç×ÓÓʼþ¹ÜÀí·þ
¡¤ÃÀ¹â·¢²¼Ê׿îSATA 6Gbps SSDÃ÷Äê
¡¤»½Æð¶ùʱµÄ¼ÇÒä  µÏÊ¿ÄáÒÆ¶¯´æ´¢
¡¤µÏÊ¿ÄáÇàíù¹úÄÚÏû·Ñµç×ÓÊг¡  Á¦
ÌØ±ðÍÆ¼ö  
08°æÍøÂç²âÊÔ¹¤¾ßÐÂÏʳö¯
¡¶ITʵÑéÊÒÖܱ¨¡·Õ÷¸åÆôÊÂ
ÖÐÎÄTraceroute£¬Â·ÓÉÐÅϢһĿÁËÈ»
±±´óÇàÄñIT½ÌÓýÇóѧÅàѵȫ¹¥ÂÔ
¹Ì̬ӲÅÌ--δÀ´´æ´¢Ö®ÐÇ
ÖÐÎÄÊÚȨAlexaÍøÕ¾ÅÅÃû²éѯ
´æ´¢¼¼Êõ  
¡¡¡¡ÏÖÔÚÎÒ×î¹ØÐĵľÍÊǹâÏËÍøÂçµÄ´«ÊäÖÊÁ¿¡¢ÓÐЧ´«Êä¾àÀëÒÔ¼°Êý¾Ý´«ÊäËÙÂʵÈÐÔÄÜÖ¸±ê£¬ÒòΪ£¬ÎÒÃǵĻú·¿ºÍÉ豸¶¼·Ö´¦Á½µØ...
¡¤Å̵ãÓ²ÅÌÁìÓòµÄ¾Å´ó»ù´¡¼¼Êõ
¡¤´æ´¢½²ÌãºÏê½âËÄ´óRAID´æ´¢
¡¤ÆÊÎöÎļþÐéÄ⻯ÒÔ¼°ËÄÖÖSANÐéÄâ¼Ü¹¹
¡¤Éî¶È½âÎöRAIDÀàÐÍ È«ÃæÍ¸ÊÓRAID 10ÓÅÊÆ
¡¤´ÅÅÌÕóÁÐÈý´ó¹Ø¼ü²¿¼þ
¡¤È«·½Î»½âÎöÐéÄâ´ø¿âÓÅÊÆÌØµã
¡¤ÔÆ´æ´¢Ó¦¸ÃÓÃÔÚʲôÑùµÄÒµÎñϵͳÖÐ
¡¤È«´ÅÅ̼ÓÃÜ£º±æ±ð¸Ã×öµÄºÍ²»¸Ã×öµÄ
²úÆ·×¨Çø  
¡¤System Storage DS8700ʵÏÖ150%ÐÔÄÜÌáÉý
¡¤ÖÐСÆóÒµ´æ´¢²úÆ·Óë·½°¸Ó¦Óõ¼¹º
¡¤Adaptec 5445Z SAS&SATAÕóÁп¨Í¼ÉÍ
¡¤¹ØÓÚÔÆ´æ´¢ÐèҪŪÇåµÄÎå´óÎÊÌâ
¡¤ÉîÈë½âÎöSSDÖÐMLCÓëSLCµÄÐÔÄܲîÒì
¡¤¶àÖØÐéÄâ»ú±¸·ÝÁ÷»¯¼õÉÙRTO
¡¤ÆÕͨӲÅÌvs¹Ì̬ӲÅÌ¡ª¡ªSSDÖµÄÇô¶àÇ®Âð
¡¤¹Ì̬ӲÅÌÆÀ²â£º80GB Intel X25-M
¡¤MLCÐÔÄÜÖ±±ÆSLC£¡º£µÁ´¬P256 SSD²âÊÔ
¡¤×î´óÈÝÁ¿500GB ÈÕÁ¢P7K500ϵÁÐÓ²Å̽âÎö
 Chinaitlab Group ÆìÏÂÍøÕ¾£º  ÖйúITʵÑéÊÒ | ÖйúIDCȦ | ´æ´¢ÊÀ½ç | Êý×ÖÍøÐ£ | 21ÊÀ¼ÍITÈ˲ÅÍø
¹ØÓÚÎÒÃÇ | ¹ã¸æ·þÎñ| ³É¹¦¿Í»§ | ºÏ×÷ýÌå | ÍøÕ¾ÀúÊ· | ÁªÏµÎÒÃÇ | ÕÐÆ¸ÐÅÏ¢ | ÃâÔðÉùÃ÷ | ÉçÇøÖ®¸è
Copyright © 2001 - 2007 All Rights Reserved
¾©ICP±¸09039051ºÅ